Fire-Rated Metal Emergency Door
Passive fire protection for emergency exits, evacuation routes, and critical openings.
Fire-rated metal emergency door available in one-leaf or two-leaf configurations and in standard or custom sizes. The leaf is made from black steel sheet with a total thickness of 38 mm, metal frame, heavy-duty door closer, metal panic bar, metal lockset with cylinder knob, stainless steel handle, and heavy metal hinges. It receives two zinc chromate anticorrosive coats and a final epoxy enamel finish in a color matched similar to the wall.
Download technical sheetTechnical sheet
| Product type | Fire-rated metal door |
| Use | Emergency door |
| Configurations | One leaf or two leaves |
| Fabrication | Standard or custom sizes |
| Standard one-leaf dimension | 1.20 x 2.10 m |
| Standard two-leaf dimension | 2.00 x 2.10 m |
| Leaf width in double configuration | 1.00 m |
| Standard height | 2.10 m |
| Frame | Metal |
| Leaf material | Black steel sheet |
| Leaf thickness | 38 mm (1.5 in) |
| Anticorrosive type | Zinc chromate |
| Final finish | Epoxy enamel |
| Color | Matched similar to the wall |
| Door closer | Heavy-duty |
| Panic bar | Metal |
| Lockset | Metal |
| Lock | With cylinder knob |
| Handle | Stainless steel |
| Hinges | Heavy metal hinges |
| Indicated panic bar height | 1.00 m |
| Indicated handle or lock height | 0.90 m |
Standard sizes for one or two leaves
These base configurations help define the fire-rated emergency door according to opening width, evacuation route, and operating requirements. STAR can fabricate custom sizes for passive fire protection projects.

One leaf
Standard 1.20 x 2.10 m size, with panic bar at 1.00 m and lock or handle at 0.90 m.

Two leaves
Standard 2.00 x 2.10 m size, with two 1.00 m leaves for wider openings and evacuation routes.
Key features
Components selected for evacuation, reliable operation, and passive protection of critical openings.
- Available in one-leaf or two-leaf configurations.
- Standard or custom-size fabrication.
- Metal panic bar for emergency exit operation.
- Heavy-duty closer for controlled closing.
- Two zinc chromate anticorrosive paint coats.
- Final epoxy enamel finish in a color matched similar to the wall.
Configured for each project
The door is defined according to opening dimensions, one-leaf or two-leaf configuration, required finish, location within the evacuation route, and installation conditions. STAR can supply and install the solution as a standalone product or as part of a complete passive fire protection strategy.
Need fire-rated emergency doors for your project?
Share opening dimensions, number of leaves, location, required finish, and installation conditions. We can help with selection and quotation.